Analysis of mechanical strength to fixing the femoral neck fracture in synthetic bone type Asnis
Autor(a) principal: | |
---|---|
Data de Publicação: | 2014 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Acta Ortopédica Brasileira (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-78522014000400206 |
Resumo: | OBJECTIVE: To analyze the results of biomechanical assays of fixation of Pauwels type III femoral neck fracture in synthetic bone, using 7.5mm cannulated screws in inverted triangle formation, in relation to the control group. METHODS: Ten synthetic bones were used, from a domestic brand, divided into two groups: test and control. In the test group, a 70° tilt osteotomy of the femoral neck was fixated using three cannulated screws in inverted triangle formation. The resistance of this fixation and its rotational deviation were analyzed at 5mm displacement (phase 1) and 10mm displacement (phase 2). The control group was tested in its integrity until the fracture of the femoral neck occurred. The Mann-Whitney test was used for group analysis and comparison. RESULTS: The values in the test group in phase 1, in samples 1-5, showed a mean of 579N and SD =77N. Rotational deviations showed a mean of 3.33°, SD = 2.63°. In phase 2, the mean was 696N and SD =106N. The values of the maximum load in the control group had a mean of 1329N and SD=177N. CONCLUSION: The analysis of mechanical strength between the groups determined a statistically significant lower value in the test group. Level of Evidence III, Control Case. |
id |
SBOT-1_021396d1adb24fd661a468cd38bef307 |
---|---|
oai_identifier_str |
oai:scielo:S1413-78522014000400206 |
network_acronym_str |
SBOT-1 |
network_name_str |
Acta Ortopédica Brasileira (Online) |
repository_id_str |
|
spelling |
Analysis of mechanical strength to fixing the femoral neck fracture in synthetic bone type AsnisFemoral neck fracturesFracture fixation, internalBiomechanical phenomena OBJECTIVE: To analyze the results of biomechanical assays of fixation of Pauwels type III femoral neck fracture in synthetic bone, using 7.5mm cannulated screws in inverted triangle formation, in relation to the control group. METHODS: Ten synthetic bones were used, from a domestic brand, divided into two groups: test and control. In the test group, a 70° tilt osteotomy of the femoral neck was fixated using three cannulated screws in inverted triangle formation. The resistance of this fixation and its rotational deviation were analyzed at 5mm displacement (phase 1) and 10mm displacement (phase 2). The control group was tested in its integrity until the fracture of the femoral neck occurred. The Mann-Whitney test was used for group analysis and comparison. RESULTS: The values in the test group in phase 1, in samples 1-5, showed a mean of 579N and SD =77N. Rotational deviations showed a mean of 3.33°, SD = 2.63°. In phase 2, the mean was 696N and SD =106N. The values of the maximum load in the control group had a mean of 1329N and SD=177N. CONCLUSION: The analysis of mechanical strength between the groups determined a statistically significant lower value in the test group. Level of Evidence III, Control Case. ATHA EDITORA2014-08-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-78522014000400206Acta Ortopédica Brasileira v.22 n.4 2014reponame:Acta Ortopédica Brasileira (Online)instname:Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)instacron:SBOT10.1590/1413-78522014220400917info:eu-repo/semantics/openAccessFreitas,AndersonLula,Welder FernandesOliveira,Jonathan Sampaio deMaciel,Rafael AlmeidaSouto,Diogo Ranier de MacedoGodinho,Patrick Fernandeseng2015-08-03T00:00:00Zoai:scielo:S1413-78522014000400206Revistahttp://www.actaortopedica.com.br/https://old.scielo.br/oai/scielo-oai.php1atha@uol.com.br||actaortopedicabrasileira@uol.com.br1809-44061413-7852opendoar:2015-08-03T00:00Acta Ortopédica Brasileira (Online) - Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)false |
dc.title.none.fl_str_mv |
Analysis of mechanical strength to fixing the femoral neck fracture in synthetic bone type Asnis |
title |
Analysis of mechanical strength to fixing the femoral neck fracture in synthetic bone type Asnis |
spellingShingle |
Analysis of mechanical strength to fixing the femoral neck fracture in synthetic bone type Asnis Freitas,Anderson Femoral neck fractures Fracture fixation, internal Biomechanical phenomena |
title_short |
Analysis of mechanical strength to fixing the femoral neck fracture in synthetic bone type Asnis |
title_full |
Analysis of mechanical strength to fixing the femoral neck fracture in synthetic bone type Asnis |
title_fullStr |
Analysis of mechanical strength to fixing the femoral neck fracture in synthetic bone type Asnis |
title_full_unstemmed |
Analysis of mechanical strength to fixing the femoral neck fracture in synthetic bone type Asnis |
title_sort |
Analysis of mechanical strength to fixing the femoral neck fracture in synthetic bone type Asnis |
author |
Freitas,Anderson |
author_facet |
Freitas,Anderson Lula,Welder Fernandes Oliveira,Jonathan Sampaio de Maciel,Rafael Almeida Souto,Diogo Ranier de Macedo Godinho,Patrick Fernandes |
author_role |
author |
author2 |
Lula,Welder Fernandes Oliveira,Jonathan Sampaio de Maciel,Rafael Almeida Souto,Diogo Ranier de Macedo Godinho,Patrick Fernandes |
author2_role |
author author author author author |
dc.contributor.author.fl_str_mv |
Freitas,Anderson Lula,Welder Fernandes Oliveira,Jonathan Sampaio de Maciel,Rafael Almeida Souto,Diogo Ranier de Macedo Godinho,Patrick Fernandes |
dc.subject.por.fl_str_mv |
Femoral neck fractures Fracture fixation, internal Biomechanical phenomena |
topic |
Femoral neck fractures Fracture fixation, internal Biomechanical phenomena |
description |
OBJECTIVE: To analyze the results of biomechanical assays of fixation of Pauwels type III femoral neck fracture in synthetic bone, using 7.5mm cannulated screws in inverted triangle formation, in relation to the control group. METHODS: Ten synthetic bones were used, from a domestic brand, divided into two groups: test and control. In the test group, a 70° tilt osteotomy of the femoral neck was fixated using three cannulated screws in inverted triangle formation. The resistance of this fixation and its rotational deviation were analyzed at 5mm displacement (phase 1) and 10mm displacement (phase 2). The control group was tested in its integrity until the fracture of the femoral neck occurred. The Mann-Whitney test was used for group analysis and comparison. RESULTS: The values in the test group in phase 1, in samples 1-5, showed a mean of 579N and SD =77N. Rotational deviations showed a mean of 3.33°, SD = 2.63°. In phase 2, the mean was 696N and SD =106N. The values of the maximum load in the control group had a mean of 1329N and SD=177N. CONCLUSION: The analysis of mechanical strength between the groups determined a statistically significant lower value in the test group. Level of Evidence III, Control Case. |
publishDate |
2014 |
dc.date.none.fl_str_mv |
2014-08-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-78522014000400206 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-78522014000400206 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/1413-78522014220400917 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
ATHA EDITORA |
publisher.none.fl_str_mv |
ATHA EDITORA |
dc.source.none.fl_str_mv |
Acta Ortopédica Brasileira v.22 n.4 2014 reponame:Acta Ortopédica Brasileira (Online) instname:Sociedade Brasileira de Ortopedia e Traumatologia (SBOT) instacron:SBOT |
instname_str |
Sociedade Brasileira de Ortopedia e Traumatologia (SBOT) |
instacron_str |
SBOT |
institution |
SBOT |
reponame_str |
Acta Ortopédica Brasileira (Online) |
collection |
Acta Ortopédica Brasileira (Online) |
repository.name.fl_str_mv |
Acta Ortopédica Brasileira (Online) - Sociedade Brasileira de Ortopedia e Traumatologia (SBOT) |
repository.mail.fl_str_mv |
1atha@uol.com.br||actaortopedicabrasileira@uol.com.br |
_version_ |
1752122275067330560 |