Comparative evaluation of the effect of various irrigants and dry canal on electronic apex locators in locating simulated root perforations: an in vitro study

Detalhes bibliográficos
Autor(a) principal: Srivastava, Swati
Data de Publicação: 2020
Outros Autores: Gaikwad, Rahul, Dalal, Alayed M
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Dental Science
Texto Completo: https://ojs.ict.unesp.br/index.php/cob/article/view/1856
Resumo: Objective: this study aimed to evaluate the effects of irrigants and dry canal on the accuracy of electronic apex locator (EAL) in locating simulated root perforations. Material and methods: twenty singlerooted, mandibular premolars were decoronated at CEJ, and the contents were removed with a barbed broach. The canals were instrumented up to a size of 15 K-file. The roots were artificially perforated at 4 mm from the anatomic apex. The actual length (AL) up to the perforation site was determined. The electronic length (EL) of perforations was obtained by Root ZX mini and iRoot in the dry canal and in the presence of 5.2% NaOCl, SmearOff, and 0.9% sodium chloride using a size 20 K-file. The differences between the EL and AL of the perforations were calculated. Statistical analyses using Friedman and Wilcoxon signed-rank tests were used to analyse the data with the level of significance set at p < 0.05. Results: there were significant differences in different canal conditions with both Root ZX mini and i Root. Measurements in dry canals were significantly longer for both apex locators (p < 0.05). Measurements with NaOCl were significantly shorter for both apex locators (p < 0.05). Both apex locators produced significantly accurate values for Saline and Smear OFF (p < 0.05). Conclusions: in this study, both Root ZX mini and i Root were affected by different canal conditions. The most accurate measurements were seen in the presence of saline and SmearOFF.KEYWORDS Electronic apex locator; I Root; Perforation; Root ZX mini; SmearOFF; Sodium hypochlorite; Saline.Keywords: Electronic apex locator, i Root, perforation, Root ZX mini, SmearOFF, sodium hypochlorite, saline 
id UNESP-20_b13bc2754dd7a65df82e08bde9d1094f
oai_identifier_str oai:ojs.pkp.sfu.ca:article/1856
network_acronym_str UNESP-20
network_name_str Brazilian Dental Science
repository_id_str
spelling Comparative evaluation of the effect of various irrigants and dry canal on electronic apex locators in locating simulated root perforations: an in vitro studyObjective: this study aimed to evaluate the effects of irrigants and dry canal on the accuracy of electronic apex locator (EAL) in locating simulated root perforations. Material and methods: twenty singlerooted, mandibular premolars were decoronated at CEJ, and the contents were removed with a barbed broach. The canals were instrumented up to a size of 15 K-file. The roots were artificially perforated at 4 mm from the anatomic apex. The actual length (AL) up to the perforation site was determined. The electronic length (EL) of perforations was obtained by Root ZX mini and iRoot in the dry canal and in the presence of 5.2% NaOCl, SmearOff, and 0.9% sodium chloride using a size 20 K-file. The differences between the EL and AL of the perforations were calculated. Statistical analyses using Friedman and Wilcoxon signed-rank tests were used to analyse the data with the level of significance set at p < 0.05. Results: there were significant differences in different canal conditions with both Root ZX mini and i Root. Measurements in dry canals were significantly longer for both apex locators (p < 0.05). Measurements with NaOCl were significantly shorter for both apex locators (p < 0.05). Both apex locators produced significantly accurate values for Saline and Smear OFF (p < 0.05). Conclusions: in this study, both Root ZX mini and i Root were affected by different canal conditions. The most accurate measurements were seen in the presence of saline and SmearOFF.KEYWORDS Electronic apex locator; I Root; Perforation; Root ZX mini; SmearOFF; Sodium hypochlorite; Saline.Keywords: Electronic apex locator, i Root, perforation, Root ZX mini, SmearOFF, sodium hypochlorite, saline Institute of Science and Technology of São José dos Campos2020-01-31info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfapplication/pdfhttps://ojs.ict.unesp.br/index.php/cob/article/view/185610.14295/bds.2020.v23i1.1856Brazilian Dental Science; Vol. 23 No. 1 (2020): Jan. - Mar. - Published Jan. 2020; 6 p.Brazilian Dental Science; v. 23 n. 1 (2020): Jan. - Mar. - Published Jan. 2020; 6 p.2178-6011reponame:Brazilian Dental Scienceinstname:Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP)instacron:UNESPenghttps://ojs.ict.unesp.br/index.php/cob/article/view/1856/1432https://ojs.ict.unesp.br/index.php/cob/article/view/1856/3883Copyright (c) 2020 Brazilian Dental Scienceinfo:eu-repo/semantics/openAccessSrivastava, SwatiGaikwad, RahulDalal, Alayed M2020-02-13T09:44:40Zoai:ojs.pkp.sfu.ca:article/1856Revistahttp://bds.ict.unesp.br/PUBhttp://ojs.fosjc.unesp.br/index.php/index/oaisergio@fosjc.unesp.br||sergio@fosjc.unesp.br2178-60112178-6011opendoar:2022-11-08T16:30:25.881155Brazilian Dental Science - Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP)true
dc.title.none.fl_str_mv Comparative evaluation of the effect of various irrigants and dry canal on electronic apex locators in locating simulated root perforations: an in vitro study
title Comparative evaluation of the effect of various irrigants and dry canal on electronic apex locators in locating simulated root perforations: an in vitro study
spellingShingle Comparative evaluation of the effect of various irrigants and dry canal on electronic apex locators in locating simulated root perforations: an in vitro study
Srivastava, Swati
title_short Comparative evaluation of the effect of various irrigants and dry canal on electronic apex locators in locating simulated root perforations: an in vitro study
title_full Comparative evaluation of the effect of various irrigants and dry canal on electronic apex locators in locating simulated root perforations: an in vitro study
title_fullStr Comparative evaluation of the effect of various irrigants and dry canal on electronic apex locators in locating simulated root perforations: an in vitro study
title_full_unstemmed Comparative evaluation of the effect of various irrigants and dry canal on electronic apex locators in locating simulated root perforations: an in vitro study
title_sort Comparative evaluation of the effect of various irrigants and dry canal on electronic apex locators in locating simulated root perforations: an in vitro study
author Srivastava, Swati
author_facet Srivastava, Swati
Gaikwad, Rahul
Dalal, Alayed M
author_role author
author2 Gaikwad, Rahul
Dalal, Alayed M
author2_role author
author
dc.contributor.author.fl_str_mv Srivastava, Swati
Gaikwad, Rahul
Dalal, Alayed M
description Objective: this study aimed to evaluate the effects of irrigants and dry canal on the accuracy of electronic apex locator (EAL) in locating simulated root perforations. Material and methods: twenty singlerooted, mandibular premolars were decoronated at CEJ, and the contents were removed with a barbed broach. The canals were instrumented up to a size of 15 K-file. The roots were artificially perforated at 4 mm from the anatomic apex. The actual length (AL) up to the perforation site was determined. The electronic length (EL) of perforations was obtained by Root ZX mini and iRoot in the dry canal and in the presence of 5.2% NaOCl, SmearOff, and 0.9% sodium chloride using a size 20 K-file. The differences between the EL and AL of the perforations were calculated. Statistical analyses using Friedman and Wilcoxon signed-rank tests were used to analyse the data with the level of significance set at p < 0.05. Results: there were significant differences in different canal conditions with both Root ZX mini and i Root. Measurements in dry canals were significantly longer for both apex locators (p < 0.05). Measurements with NaOCl were significantly shorter for both apex locators (p < 0.05). Both apex locators produced significantly accurate values for Saline and Smear OFF (p < 0.05). Conclusions: in this study, both Root ZX mini and i Root were affected by different canal conditions. The most accurate measurements were seen in the presence of saline and SmearOFF.KEYWORDS Electronic apex locator; I Root; Perforation; Root ZX mini; SmearOFF; Sodium hypochlorite; Saline.Keywords: Electronic apex locator, i Root, perforation, Root ZX mini, SmearOFF, sodium hypochlorite, saline 
publishDate 2020
dc.date.none.fl_str_mv 2020-01-31
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://ojs.ict.unesp.br/index.php/cob/article/view/1856
10.14295/bds.2020.v23i1.1856
url https://ojs.ict.unesp.br/index.php/cob/article/view/1856
identifier_str_mv 10.14295/bds.2020.v23i1.1856
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://ojs.ict.unesp.br/index.php/cob/article/view/1856/1432
https://ojs.ict.unesp.br/index.php/cob/article/view/1856/3883
dc.rights.driver.fl_str_mv Copyright (c) 2020 Brazilian Dental Science
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Copyright (c) 2020 Brazilian Dental Science
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
application/pdf
dc.publisher.none.fl_str_mv Institute of Science and Technology of São José dos Campos
publisher.none.fl_str_mv Institute of Science and Technology of São José dos Campos
dc.source.none.fl_str_mv Brazilian Dental Science; Vol. 23 No. 1 (2020): Jan. - Mar. - Published Jan. 2020; 6 p.
Brazilian Dental Science; v. 23 n. 1 (2020): Jan. - Mar. - Published Jan. 2020; 6 p.
2178-6011
reponame:Brazilian Dental Science
instname:Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Brazilian Dental Science
collection Brazilian Dental Science
repository.name.fl_str_mv Brazilian Dental Science - Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP)
repository.mail.fl_str_mv sergio@fosjc.unesp.br||sergio@fosjc.unesp.br
_version_ 1788346901334065152