Texto Completo: https://rsdjournal.org/index.php/rsd/article/view/17217
Resumo: Taking advantage of embankments with steep slopes and great heights often means adopting more elaborate solutions, such as the application of geosynthetics in reinforced walls. This article presents the dimensioning of a wall reinforced with geosynthetic for stabilization of a slope located in the area of the Jordão Reservoir, Recife - Pernambuco, in order to alter the initial design of containment in gabion wall of the same embankment. The dimensioning of the reinforced wall is carried out considering the criteria in the analysis of the external and internal stability of the structure, and the proposal for alteration in the initial surface drainage project is also indicated so that the slope stability. In the analysis of external stability, there was a reinforcement length of 5,86 m, which met both the slip and tip safety factor. In the analysis of internal stability using the Jewell method (1991), a reinforcement length of 5,28 m was obtained. Then, adopting the longest reinforcement length among the results of the analyzes, obeying the minimum lengths required in all stability criteria. The results obtained showed that the wall reinforced with geosynthetic for stabilization of the slope Laser Electro and the geotechnical and geometric parameters involved were adequate to the project, being a safe solution for faces of the walls or more vertical slopes.
id UNIFEI_eca0479bc185d6919f9a5e2db47aa538
oai_identifier_str oai:ojs.pkp.sfu.ca:article/17217
network_acronym_str UNIFEI
network_name_str Research, Society and Development
repository_id_str
spelling Sizing of a retaining structure in a wall reinforced with geosyntheticsDimensionamiento de estructura de contención en muro reforzado con geossintéticosDimensionamento de uma estrutura de contenção em muro reforçado com geossintéticoStability analysisGeosyntheticsReinforcement.Análisis de estabilidadGeosintéticosReforzamiento.Análise de estabilidadeGeossintéticosReforço.Taking advantage of embankments with steep slopes and great heights often means adopting more elaborate solutions, such as the application of geosynthetics in reinforced walls. This article presents the dimensioning of a wall reinforced with geosynthetic for stabilization of a slope located in the area of the Jordão Reservoir, Recife - Pernambuco, in order to alter the initial design of containment in gabion wall of the same embankment. The dimensioning of the reinforced wall is carried out considering the criteria in the analysis of the external and internal stability of the structure, and the proposal for alteration in the initial surface drainage project is also indicated so that the slope stability. In the analysis of external stability, there was a reinforcement length of 5,86 m, which met both the slip and tip safety factor. In the analysis of internal stability using the Jewell method (1991), a reinforcement length of 5,28 m was obtained. Then, adopting the longest reinforcement length among the results of the analyzes, obeying the minimum lengths required in all stability criteria. The results obtained showed that the wall reinforced with geosynthetic for stabilization of the slope Laser Electro and the geotechnical and geometric parameters involved were adequate to the project, being a safe solution for faces of the walls or more vertical slopes.Aprovechar áreas de pendiente con pendientes pronunciadas y grandes alturas a menudo significa adoptar soluciones más elaboradas, como la aplicación de geosintéticos en muros reforzados. Este artículo presenta el dimensionamiento de un muro reforzado con geosintético para la estabilización de un talud ubicado en el área del Embalse de Jordão, Recife - Pernambuco, con el fin de alterar el diseño inicial de contención en muro de gaviones del mismo terraplén. El dimensionamiento del muro armado se realiza considerando los criterios en el análisis de la estabilidad externa e interna de la estructura, y también se indica la propuesta de alteración en el proyecto de drenaje superficial inicial para que la estabilidad del talud. En el análisis de estabilidad exterior, se encontró una longitud de refuerzo de 5,86 m, que cumplió tanto con el factor de seguridad para deslizamientos como para vuelco. En el análisis de estabilidad interna mediante el método de Jewell (1991), se obtuvo una longitud de refuerzo de 5,28 m. Luego, adoptando la longitud de refuerzo más larga entre los resultados de los análisis, obedeciendo las longitudes mínimas requeridas en todos los criterios de estabilidad. Los resultados obtenidos mostraron que el muro reforzado con geosintético para estabilización del talud Laser Electro y los parámetros geotécnicos y geométricos involucrados fueron adecuados al proyecto, siendo una solución segura para paramentos de los muros o taludes más verticales.Aproveitar áreas de taludes com inclinações acentuadas e grandes alturas muitas vezes significa adotar soluções mais elaboradas, como a aplicação de geossintéticos em muros reforçados. Este artigo apresenta o dimensionamento de um muro reforçado com geossintético para estabilização de uma encosta localizada na área do Reservatório do Jordão, Recife – Pernambuco, com objetivo de alterar o projeto inicial de contenção em muro de gabião do mesmo talude. O dimensionamento do muro reforçado é realizado considerando os critérios na análise da estabilidade externa e interna da estrutura, sendo também indicada a proposta de alteração no projeto inicial de drenagem superficial para que a estabilidade da encosta. Na análise da estabilidade externa, verificou-se um comprimento do reforço de 5,86 m, que atendia tanto ao fator de segurança ao deslizamento como ao tombamento. Na análise da estabilidade interna pelo método de Jewell (1991) obteve-se um comprimento de reforço de 5,28 m. Adotando-se então o maior comprimento de reforço entre os resultados das análises obedecendo os comprimentos mínimos exigidos em todos os critérios de estabilidade. Os resultados obtidos mostraram que o muro reforçado com geossintético para estabilização da encosta Laser Eletro e os parâmetros geotécnicos e geométricos envolvidos foram adequados ao projeto, sendo uma solução segura para faces dos muros ou taludes mais verticalizados.Research, Society and Development2021-07-09info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://rsdjournal.org/index.php/rsd/article/view/1721710.33448/rsd-v10i8.17217Research, Society and Development; Vol. 10 No. 8; e14210817217Research, Society and Development; Vol. 10 Núm. 8; e14210817217Research, Society and Development; v. 10 n. 8; e142108172172525-3409reponame:Research, Society and Developmentinstname:Universidade Federal de Itajubá (UNIFEI)instacron:UNIFEIporhttps://rsdjournal.org/index.php/rsd/article/view/17217/15325Copyright (c) 2021 Elton Douglas Galino Gomes; Fabiola de Souza Gomes; Maria Isabela Marques da Cunha Vieira Bello; Iálysson da Silva Medeiros; Martha Maria Bezerra Santos; Silvio Romero de Melo Ferreirahttps://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessGomes, Elton Douglas GalinoGomes, Fabiola de SouzaBello, Maria Isabela Marques da Cunha VieiraMedeiros, Iálysson da SilvaSantos, Martha Maria BezerraFerreira, Silvio Romero de Melo2021-08-21T18:46:59Zoai:ojs.pkp.sfu.ca:article/17217Revistahttps://rsdjournal.org/index.php/rsd/indexPUBhttps://rsdjournal.org/index.php/rsd/oairsd.articles@gmail.com2525-34092525-3409opendoar:2024-01-17T09:37:36.186042Research, Society and Development - Universidade Federal de Itajubá (UNIFEI)false
dc.title.none.fl_str_mv Sizing of a retaining structure in a wall reinforced with geosynthetics
Dimensionamiento de estructura de contención en muro reforzado con geossintéticos
Dimensionamento de uma estrutura de contenção em muro reforçado com geossintético
title Sizing of a retaining structure in a wall reinforced with geosynthetics
spellingShingle Sizing of a retaining structure in a wall reinforced with geosynthetics
Gomes, Elton Douglas Galino
Stability analysis
Geosynthetics
Reinforcement.
Análisis de estabilidad
Geosintéticos
Reforzamiento.
Análise de estabilidade
Geossintéticos
Reforço.
title_short Sizing of a retaining structure in a wall reinforced with geosynthetics
title_full Sizing of a retaining structure in a wall reinforced with geosynthetics
title_fullStr Sizing of a retaining structure in a wall reinforced with geosynthetics
title_full_unstemmed Sizing of a retaining structure in a wall reinforced with geosynthetics
title_sort Sizing of a retaining structure in a wall reinforced with geosynthetics
author Gomes, Elton Douglas Galino
author_facet Gomes, Elton Douglas Galino
Gomes, Fabiola de Souza
Bello, Maria Isabela Marques da Cunha Vieira
Medeiros, Iálysson da Silva
Santos, Martha Maria Bezerra
Ferreira, Silvio Romero de Melo
author_role author
author2 Gomes, Fabiola de Souza
Bello, Maria Isabela Marques da Cunha Vieira
Medeiros, Iálysson da Silva
Santos, Martha Maria Bezerra
Ferreira, Silvio Romero de Melo
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Gomes, Elton Douglas Galino
Gomes, Fabiola de Souza
Bello, Maria Isabela Marques da Cunha Vieira
Medeiros, Iálysson da Silva
Santos, Martha Maria Bezerra
Ferreira, Silvio Romero de Melo
dc.subject.por.fl_str_mv Stability analysis
Geosynthetics
Reinforcement.
Análisis de estabilidad
Geosintéticos
Reforzamiento.
Análise de estabilidade
Geossintéticos
Reforço.
topic Stability analysis
Geosynthetics
Reinforcement.
Análisis de estabilidad
Geosintéticos
Reforzamiento.
Análise de estabilidade
Geossintéticos
Reforço.
description Taking advantage of embankments with steep slopes and great heights often means adopting more elaborate solutions, such as the application of geosynthetics in reinforced walls. This article presents the dimensioning of a wall reinforced with geosynthetic for stabilization of a slope located in the area of the Jordão Reservoir, Recife - Pernambuco, in order to alter the initial design of containment in gabion wall of the same embankment. The dimensioning of the reinforced wall is carried out considering the criteria in the analysis of the external and internal stability of the structure, and the proposal for alteration in the initial surface drainage project is also indicated so that the slope stability. In the analysis of external stability, there was a reinforcement length of 5,86 m, which met both the slip and tip safety factor. In the analysis of internal stability using the Jewell method (1991), a reinforcement length of 5,28 m was obtained. Then, adopting the longest reinforcement length among the results of the analyzes, obeying the minimum lengths required in all stability criteria. The results obtained showed that the wall reinforced with geosynthetic for stabilization of the slope Laser Electro and the geotechnical and geometric parameters involved were adequate to the project, being a safe solution for faces of the walls or more vertical slopes.
publishDate 2021
dc.date.none.fl_str_mv 2021-07-09
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://rsdjournal.org/index.php/rsd/article/view/17217
10.33448/rsd-v10i8.17217
url https://rsdjournal.org/index.php/rsd/article/view/17217
identifier_str_mv 10.33448/rsd-v10i8.17217
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv https://rsdjournal.org/index.php/rsd/article/view/17217/15325
dc.rights.driver.fl_str_mv https://creativecommons.org/licenses/by/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Research, Society and Development
publisher.none.fl_str_mv Research, Society and Development
dc.source.none.fl_str_mv Research, Society and Development; Vol. 10 No. 8; e14210817217
Research, Society and Development; Vol. 10 Núm. 8; e14210817217
Research, Society and Development; v. 10 n. 8; e14210817217
2525-3409
reponame:Research, Society and Development
instname:Universidade Federal de Itajubá (UNIFEI)
instacron:UNIFEI
instname_str Universidade Federal de Itajubá (UNIFEI)
instacron_str UNIFEI
institution UNIFEI
reponame_str Research, Society and Development
collection Research, Society and Development
repository.name.fl_str_mv Research, Society and Development - Universidade Federal de Itajubá (UNIFEI)
repository.mail.fl_str_mv rsd.articles@gmail.com
_version_ 1797052681757392896