Renal perfusion evaluation by alternating current biosusceptometry of magnetic nanoparticles

Detalhes bibliográficos
Autor(a) principal: Quini, Caio C. [UNESP]
Data de Publicação: 2015
Outros Autores: Matos, Juliana F. [UNESP], Próspero, André G. [UNESP], Calabresi, Marcos Felipe F. [UNESP], Zufelato, Nicholas, Bakuzis, Andris F., Baffa, Oswaldo, Miranda, José Ricardo A. [UNESP]
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://dx.doi.org/10.1016/j.jmmm.2014.09.073
http://hdl.handle.net/11449/170046
Resumo: Alternating current susceptometry, a simple and affordable technique, was employed to study the sensitivity of this approach to assess rat kidney perfusion by the injection of 200 μL of magnetic nanoparticles with a concentration of 23 mg/mL in the femoral vein and the measurement of the signal above the kidney. The instrument was able to detect the signal and the transit time of the first and second pass were measured in five animals with average values of 13.6±4.3 s and 20.6±7.1 s.
id UNSP_1a007f9b8e3f2756735bb0b9afe0fc73
oai_identifier_str oai:repositorio.unesp.br:11449/170046
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Renal perfusion evaluation by alternating current biosusceptometry of magnetic nanoparticlesAlternating current susceptometry, a simple and affordable technique, was employed to study the sensitivity of this approach to assess rat kidney perfusion by the injection of 200 μL of magnetic nanoparticles with a concentration of 23 mg/mL in the femoral vein and the measurement of the signal above the kidney. The instrument was able to detect the signal and the transit time of the first and second pass were measured in five animals with average values of 13.6±4.3 s and 20.6±7.1 s.Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)Departamento de Física e Biofísica Instituto de Biociências UNESPInstituto de Física UFGDepartamento de Física FFCLRP USPDepartamento de Física e Biofísica Instituto de Biociências UNESPFAPESP: 2010/07639-9FAPESP: 2011/18696-6Universidade Estadual Paulista (Unesp)UFGUniversidade de São Paulo (USP)Quini, Caio C. [UNESP]Matos, Juliana F. [UNESP]Próspero, André G. [UNESP]Calabresi, Marcos Felipe F. [UNESP]Zufelato, NicholasBakuzis, Andris F.Baffa, OswaldoMiranda, José Ricardo A. [UNESP]2018-12-11T16:48:52Z2018-12-11T16:48:52Z2015-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article2-6application/pdfhttp://dx.doi.org/10.1016/j.jmmm.2014.09.073Journal of Magnetism and Magnetic Materials, v. 380, p. 2-6.0304-8853http://hdl.handle.net/11449/17004610.1016/j.jmmm.2014.09.0732-s2.0-850279171972-s2.0-85027917197.pdfScopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengJournal of Magnetism and Magnetic Materials0,786info:eu-repo/semantics/openAccess2024-01-03T06:20:50Zoai:repositorio.unesp.br:11449/170046Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T22:00:03.388079Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Renal perfusion evaluation by alternating current biosusceptometry of magnetic nanoparticles
title Renal perfusion evaluation by alternating current biosusceptometry of magnetic nanoparticles
spellingShingle Renal perfusion evaluation by alternating current biosusceptometry of magnetic nanoparticles
Quini, Caio C. [UNESP]
title_short Renal perfusion evaluation by alternating current biosusceptometry of magnetic nanoparticles
title_full Renal perfusion evaluation by alternating current biosusceptometry of magnetic nanoparticles
title_fullStr Renal perfusion evaluation by alternating current biosusceptometry of magnetic nanoparticles
title_full_unstemmed Renal perfusion evaluation by alternating current biosusceptometry of magnetic nanoparticles
title_sort Renal perfusion evaluation by alternating current biosusceptometry of magnetic nanoparticles
author Quini, Caio C. [UNESP]
author_facet Quini, Caio C. [UNESP]
Matos, Juliana F. [UNESP]
Próspero, André G. [UNESP]
Calabresi, Marcos Felipe F. [UNESP]
Zufelato, Nicholas
Bakuzis, Andris F.
Baffa, Oswaldo
Miranda, José Ricardo A. [UNESP]
author_role author
author2 Matos, Juliana F. [UNESP]
Próspero, André G. [UNESP]
Calabresi, Marcos Felipe F. [UNESP]
Zufelato, Nicholas
Bakuzis, Andris F.
Baffa, Oswaldo
Miranda, José Ricardo A. [UNESP]
author2_role author
author
author
author
author
author
author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (Unesp)
UFG
Universidade de São Paulo (USP)
dc.contributor.author.fl_str_mv Quini, Caio C. [UNESP]
Matos, Juliana F. [UNESP]
Próspero, André G. [UNESP]
Calabresi, Marcos Felipe F. [UNESP]
Zufelato, Nicholas
Bakuzis, Andris F.
Baffa, Oswaldo
Miranda, José Ricardo A. [UNESP]
description Alternating current susceptometry, a simple and affordable technique, was employed to study the sensitivity of this approach to assess rat kidney perfusion by the injection of 200 μL of magnetic nanoparticles with a concentration of 23 mg/mL in the femoral vein and the measurement of the signal above the kidney. The instrument was able to detect the signal and the transit time of the first and second pass were measured in five animals with average values of 13.6±4.3 s and 20.6±7.1 s.
publishDate 2015
dc.date.none.fl_str_mv 2015-01-01
2018-12-11T16:48:52Z
2018-12-11T16:48:52Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1016/j.jmmm.2014.09.073
Journal of Magnetism and Magnetic Materials, v. 380, p. 2-6.
0304-8853
http://hdl.handle.net/11449/170046
10.1016/j.jmmm.2014.09.073
2-s2.0-85027917197
2-s2.0-85027917197.pdf
url http://dx.doi.org/10.1016/j.jmmm.2014.09.073
http://hdl.handle.net/11449/170046
identifier_str_mv Journal of Magnetism and Magnetic Materials, v. 380, p. 2-6.
0304-8853
10.1016/j.jmmm.2014.09.073
2-s2.0-85027917197
2-s2.0-85027917197.pdf
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Journal of Magnetism and Magnetic Materials
0,786
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 2-6
application/pdf
dc.source.none.fl_str_mv Scopus
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1808129382454132736