Renal perfusion evaluation by alternating current biosusceptometry of magnetic nanoparticles
Autor(a) principal: | |
---|---|
Data de Publicação: | 2015 |
Outros Autores: | , , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNESP |
Texto Completo: | http://dx.doi.org/10.1016/j.jmmm.2014.09.073 http://hdl.handle.net/11449/170046 |
Resumo: | Alternating current susceptometry, a simple and affordable technique, was employed to study the sensitivity of this approach to assess rat kidney perfusion by the injection of 200 μL of magnetic nanoparticles with a concentration of 23 mg/mL in the femoral vein and the measurement of the signal above the kidney. The instrument was able to detect the signal and the transit time of the first and second pass were measured in five animals with average values of 13.6±4.3 s and 20.6±7.1 s. |
id |
UNSP_1a007f9b8e3f2756735bb0b9afe0fc73 |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/170046 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
Renal perfusion evaluation by alternating current biosusceptometry of magnetic nanoparticlesAlternating current susceptometry, a simple and affordable technique, was employed to study the sensitivity of this approach to assess rat kidney perfusion by the injection of 200 μL of magnetic nanoparticles with a concentration of 23 mg/mL in the femoral vein and the measurement of the signal above the kidney. The instrument was able to detect the signal and the transit time of the first and second pass were measured in five animals with average values of 13.6±4.3 s and 20.6±7.1 s.Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)Departamento de Física e Biofísica Instituto de Biociências UNESPInstituto de Física UFGDepartamento de Física FFCLRP USPDepartamento de Física e Biofísica Instituto de Biociências UNESPFAPESP: 2010/07639-9FAPESP: 2011/18696-6Universidade Estadual Paulista (Unesp)UFGUniversidade de São Paulo (USP)Quini, Caio C. [UNESP]Matos, Juliana F. [UNESP]Próspero, André G. [UNESP]Calabresi, Marcos Felipe F. [UNESP]Zufelato, NicholasBakuzis, Andris F.Baffa, OswaldoMiranda, José Ricardo A. [UNESP]2018-12-11T16:48:52Z2018-12-11T16:48:52Z2015-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article2-6application/pdfhttp://dx.doi.org/10.1016/j.jmmm.2014.09.073Journal of Magnetism and Magnetic Materials, v. 380, p. 2-6.0304-8853http://hdl.handle.net/11449/17004610.1016/j.jmmm.2014.09.0732-s2.0-850279171972-s2.0-85027917197.pdfScopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengJournal of Magnetism and Magnetic Materials0,786info:eu-repo/semantics/openAccess2024-01-03T06:20:50Zoai:repositorio.unesp.br:11449/170046Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T22:00:03.388079Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
Renal perfusion evaluation by alternating current biosusceptometry of magnetic nanoparticles |
title |
Renal perfusion evaluation by alternating current biosusceptometry of magnetic nanoparticles |
spellingShingle |
Renal perfusion evaluation by alternating current biosusceptometry of magnetic nanoparticles Quini, Caio C. [UNESP] |
title_short |
Renal perfusion evaluation by alternating current biosusceptometry of magnetic nanoparticles |
title_full |
Renal perfusion evaluation by alternating current biosusceptometry of magnetic nanoparticles |
title_fullStr |
Renal perfusion evaluation by alternating current biosusceptometry of magnetic nanoparticles |
title_full_unstemmed |
Renal perfusion evaluation by alternating current biosusceptometry of magnetic nanoparticles |
title_sort |
Renal perfusion evaluation by alternating current biosusceptometry of magnetic nanoparticles |
author |
Quini, Caio C. [UNESP] |
author_facet |
Quini, Caio C. [UNESP] Matos, Juliana F. [UNESP] Próspero, André G. [UNESP] Calabresi, Marcos Felipe F. [UNESP] Zufelato, Nicholas Bakuzis, Andris F. Baffa, Oswaldo Miranda, José Ricardo A. [UNESP] |
author_role |
author |
author2 |
Matos, Juliana F. [UNESP] Próspero, André G. [UNESP] Calabresi, Marcos Felipe F. [UNESP] Zufelato, Nicholas Bakuzis, Andris F. Baffa, Oswaldo Miranda, José Ricardo A. [UNESP] |
author2_role |
author author author author author author author |
dc.contributor.none.fl_str_mv |
Universidade Estadual Paulista (Unesp) UFG Universidade de São Paulo (USP) |
dc.contributor.author.fl_str_mv |
Quini, Caio C. [UNESP] Matos, Juliana F. [UNESP] Próspero, André G. [UNESP] Calabresi, Marcos Felipe F. [UNESP] Zufelato, Nicholas Bakuzis, Andris F. Baffa, Oswaldo Miranda, José Ricardo A. [UNESP] |
description |
Alternating current susceptometry, a simple and affordable technique, was employed to study the sensitivity of this approach to assess rat kidney perfusion by the injection of 200 μL of magnetic nanoparticles with a concentration of 23 mg/mL in the femoral vein and the measurement of the signal above the kidney. The instrument was able to detect the signal and the transit time of the first and second pass were measured in five animals with average values of 13.6±4.3 s and 20.6±7.1 s. |
publishDate |
2015 |
dc.date.none.fl_str_mv |
2015-01-01 2018-12-11T16:48:52Z 2018-12-11T16:48:52Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.1016/j.jmmm.2014.09.073 Journal of Magnetism and Magnetic Materials, v. 380, p. 2-6. 0304-8853 http://hdl.handle.net/11449/170046 10.1016/j.jmmm.2014.09.073 2-s2.0-85027917197 2-s2.0-85027917197.pdf |
url |
http://dx.doi.org/10.1016/j.jmmm.2014.09.073 http://hdl.handle.net/11449/170046 |
identifier_str_mv |
Journal of Magnetism and Magnetic Materials, v. 380, p. 2-6. 0304-8853 10.1016/j.jmmm.2014.09.073 2-s2.0-85027917197 2-s2.0-85027917197.pdf |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Journal of Magnetism and Magnetic Materials 0,786 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
2-6 application/pdf |
dc.source.none.fl_str_mv |
Scopus reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
|
_version_ |
1808129382454132736 |