Tooth embedding medium influences the accuracy of electronic apex locator

Detalhes bibliográficos
Autor(a) principal: Guerreiro-Tanomaru, Juliane M
Data de Publicação: 2012
Outros Autores: Croti, Hugo R, Silva, Guilherme F, Faria, Gisele [UNESP], Tanomaru-Filho, Mário
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://www.actaodontologicalat.com/archivo/v25n2/fulltext/art10.pdf
http://hdl.handle.net/11449/73971
Resumo: This study evaluated the influence of tooth embedding media on the accuracy ofan electronic apex locator. The root canal length of 20 human mandibular canines was measured by inserting a 15 K-file into the root canal up to the apical foramen. The distance was measured with a digital caliper. The embedding media evaluated were alginate, saline, floral foam or gauze soaked in saline. Electronic root canal length measurement was performed with Root ZX II. Data were analysed using ANOVA for repeated measurements and Tukey test, at a significance level of 5%. There was no difference between the actual root canal length measurement and the electronic reading recorded with alginate medium. The readings obtained with the other media differed from the actual root canal length measurements. Alginate provided greater accuracy in electronic root canal length determination by Root ZX II than saline, floral foam and gauze.
id UNSP_2b9c07f8bb7f09d1d7f99456c94c2662
oai_identifier_str oai:repositorio.unesp.br:11449/73971
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Tooth embedding medium influences the accuracy of electronic apex locatorendodonticshistologyhumanreproducibilitytooth rootHumansReproducibility of ResultsRoot Canal PreparationTooth ApexThis study evaluated the influence of tooth embedding media on the accuracy ofan electronic apex locator. The root canal length of 20 human mandibular canines was measured by inserting a 15 K-file into the root canal up to the apical foramen. The distance was measured with a digital caliper. The embedding media evaluated were alginate, saline, floral foam or gauze soaked in saline. Electronic root canal length measurement was performed with Root ZX II. Data were analysed using ANOVA for repeated measurements and Tukey test, at a significance level of 5%. There was no difference between the actual root canal length measurement and the electronic reading recorded with alginate medium. The readings obtained with the other media differed from the actual root canal length measurements. Alginate provided greater accuracy in electronic root canal length determination by Root ZX II than saline, floral foam and gauze.Universidade Estadual Paulista (Unesp)Guerreiro-Tanomaru, Juliane MCroti, Hugo RSilva, Guilherme FFaria, Gisele [UNESP]Tanomaru-Filho, Mário2014-05-27T11:27:23Z2014-05-27T11:27:23Z2012-12-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article214-217http://www.actaodontologicalat.com/archivo/v25n2/fulltext/art10.pdfActa odontológica latinoamericana : AOL, v. 25, n. 2, p. 214-217, 2012.0326-4815http://hdl.handle.net/11449/739712-s2.0-848726832041411074363039082Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengActa Odontológica Latinoamericana (AOL)0,264info:eu-repo/semantics/openAccess2024-09-27T18:04:54Zoai:repositorio.unesp.br:11449/73971Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestrepositoriounesp@unesp.bropendoar:29462024-09-27T18:04:54Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Tooth embedding medium influences the accuracy of electronic apex locator
title Tooth embedding medium influences the accuracy of electronic apex locator
spellingShingle Tooth embedding medium influences the accuracy of electronic apex locator
Guerreiro-Tanomaru, Juliane M
endodontics
histology
human
reproducibility
tooth root
Humans
Reproducibility of Results
Root Canal Preparation
Tooth Apex
title_short Tooth embedding medium influences the accuracy of electronic apex locator
title_full Tooth embedding medium influences the accuracy of electronic apex locator
title_fullStr Tooth embedding medium influences the accuracy of electronic apex locator
title_full_unstemmed Tooth embedding medium influences the accuracy of electronic apex locator
title_sort Tooth embedding medium influences the accuracy of electronic apex locator
author Guerreiro-Tanomaru, Juliane M
author_facet Guerreiro-Tanomaru, Juliane M
Croti, Hugo R
Silva, Guilherme F
Faria, Gisele [UNESP]
Tanomaru-Filho, Mário
author_role author
author2 Croti, Hugo R
Silva, Guilherme F
Faria, Gisele [UNESP]
Tanomaru-Filho, Mário
author2_role author
author
author
author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (Unesp)
dc.contributor.author.fl_str_mv Guerreiro-Tanomaru, Juliane M
Croti, Hugo R
Silva, Guilherme F
Faria, Gisele [UNESP]
Tanomaru-Filho, Mário
dc.subject.por.fl_str_mv endodontics
histology
human
reproducibility
tooth root
Humans
Reproducibility of Results
Root Canal Preparation
Tooth Apex
topic endodontics
histology
human
reproducibility
tooth root
Humans
Reproducibility of Results
Root Canal Preparation
Tooth Apex
description This study evaluated the influence of tooth embedding media on the accuracy ofan electronic apex locator. The root canal length of 20 human mandibular canines was measured by inserting a 15 K-file into the root canal up to the apical foramen. The distance was measured with a digital caliper. The embedding media evaluated were alginate, saline, floral foam or gauze soaked in saline. Electronic root canal length measurement was performed with Root ZX II. Data were analysed using ANOVA for repeated measurements and Tukey test, at a significance level of 5%. There was no difference between the actual root canal length measurement and the electronic reading recorded with alginate medium. The readings obtained with the other media differed from the actual root canal length measurements. Alginate provided greater accuracy in electronic root canal length determination by Root ZX II than saline, floral foam and gauze.
publishDate 2012
dc.date.none.fl_str_mv 2012-12-01
2014-05-27T11:27:23Z
2014-05-27T11:27:23Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://www.actaodontologicalat.com/archivo/v25n2/fulltext/art10.pdf
Acta odontológica latinoamericana : AOL, v. 25, n. 2, p. 214-217, 2012.
0326-4815
http://hdl.handle.net/11449/73971
2-s2.0-84872683204
1411074363039082
url http://www.actaodontologicalat.com/archivo/v25n2/fulltext/art10.pdf
http://hdl.handle.net/11449/73971
identifier_str_mv Acta odontológica latinoamericana : AOL, v. 25, n. 2, p. 214-217, 2012.
0326-4815
2-s2.0-84872683204
1411074363039082
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Acta Odontológica Latinoamericana (AOL)
0,264
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 214-217
dc.source.none.fl_str_mv Scopus
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv repositoriounesp@unesp.br
_version_ 1813546517381775360