Tooth embedding medium influences the accuracy of electronic apex locator
Autor(a) principal: | |
---|---|
Data de Publicação: | 2012 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNESP |
Texto Completo: | http://www.actaodontologicalat.com/archivo/v25n2/fulltext/art10.pdf http://hdl.handle.net/11449/73971 |
Resumo: | This study evaluated the influence of tooth embedding media on the accuracy ofan electronic apex locator. The root canal length of 20 human mandibular canines was measured by inserting a 15 K-file into the root canal up to the apical foramen. The distance was measured with a digital caliper. The embedding media evaluated were alginate, saline, floral foam or gauze soaked in saline. Electronic root canal length measurement was performed with Root ZX II. Data were analysed using ANOVA for repeated measurements and Tukey test, at a significance level of 5%. There was no difference between the actual root canal length measurement and the electronic reading recorded with alginate medium. The readings obtained with the other media differed from the actual root canal length measurements. Alginate provided greater accuracy in electronic root canal length determination by Root ZX II than saline, floral foam and gauze. |
id |
UNSP_2b9c07f8bb7f09d1d7f99456c94c2662 |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/73971 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
Tooth embedding medium influences the accuracy of electronic apex locatorendodonticshistologyhumanreproducibilitytooth rootHumansReproducibility of ResultsRoot Canal PreparationTooth ApexThis study evaluated the influence of tooth embedding media on the accuracy ofan electronic apex locator. The root canal length of 20 human mandibular canines was measured by inserting a 15 K-file into the root canal up to the apical foramen. The distance was measured with a digital caliper. The embedding media evaluated were alginate, saline, floral foam or gauze soaked in saline. Electronic root canal length measurement was performed with Root ZX II. Data were analysed using ANOVA for repeated measurements and Tukey test, at a significance level of 5%. There was no difference between the actual root canal length measurement and the electronic reading recorded with alginate medium. The readings obtained with the other media differed from the actual root canal length measurements. Alginate provided greater accuracy in electronic root canal length determination by Root ZX II than saline, floral foam and gauze.Universidade Estadual Paulista (Unesp)Guerreiro-Tanomaru, Juliane MCroti, Hugo RSilva, Guilherme FFaria, Gisele [UNESP]Tanomaru-Filho, Mário2014-05-27T11:27:23Z2014-05-27T11:27:23Z2012-12-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article214-217http://www.actaodontologicalat.com/archivo/v25n2/fulltext/art10.pdfActa odontológica latinoamericana : AOL, v. 25, n. 2, p. 214-217, 2012.0326-4815http://hdl.handle.net/11449/739712-s2.0-848726832041411074363039082Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengActa Odontológica Latinoamericana (AOL)0,264info:eu-repo/semantics/openAccess2024-09-27T18:04:54Zoai:repositorio.unesp.br:11449/73971Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestrepositoriounesp@unesp.bropendoar:29462024-09-27T18:04:54Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
Tooth embedding medium influences the accuracy of electronic apex locator |
title |
Tooth embedding medium influences the accuracy of electronic apex locator |
spellingShingle |
Tooth embedding medium influences the accuracy of electronic apex locator Guerreiro-Tanomaru, Juliane M endodontics histology human reproducibility tooth root Humans Reproducibility of Results Root Canal Preparation Tooth Apex |
title_short |
Tooth embedding medium influences the accuracy of electronic apex locator |
title_full |
Tooth embedding medium influences the accuracy of electronic apex locator |
title_fullStr |
Tooth embedding medium influences the accuracy of electronic apex locator |
title_full_unstemmed |
Tooth embedding medium influences the accuracy of electronic apex locator |
title_sort |
Tooth embedding medium influences the accuracy of electronic apex locator |
author |
Guerreiro-Tanomaru, Juliane M |
author_facet |
Guerreiro-Tanomaru, Juliane M Croti, Hugo R Silva, Guilherme F Faria, Gisele [UNESP] Tanomaru-Filho, Mário |
author_role |
author |
author2 |
Croti, Hugo R Silva, Guilherme F Faria, Gisele [UNESP] Tanomaru-Filho, Mário |
author2_role |
author author author author |
dc.contributor.none.fl_str_mv |
Universidade Estadual Paulista (Unesp) |
dc.contributor.author.fl_str_mv |
Guerreiro-Tanomaru, Juliane M Croti, Hugo R Silva, Guilherme F Faria, Gisele [UNESP] Tanomaru-Filho, Mário |
dc.subject.por.fl_str_mv |
endodontics histology human reproducibility tooth root Humans Reproducibility of Results Root Canal Preparation Tooth Apex |
topic |
endodontics histology human reproducibility tooth root Humans Reproducibility of Results Root Canal Preparation Tooth Apex |
description |
This study evaluated the influence of tooth embedding media on the accuracy ofan electronic apex locator. The root canal length of 20 human mandibular canines was measured by inserting a 15 K-file into the root canal up to the apical foramen. The distance was measured with a digital caliper. The embedding media evaluated were alginate, saline, floral foam or gauze soaked in saline. Electronic root canal length measurement was performed with Root ZX II. Data were analysed using ANOVA for repeated measurements and Tukey test, at a significance level of 5%. There was no difference between the actual root canal length measurement and the electronic reading recorded with alginate medium. The readings obtained with the other media differed from the actual root canal length measurements. Alginate provided greater accuracy in electronic root canal length determination by Root ZX II than saline, floral foam and gauze. |
publishDate |
2012 |
dc.date.none.fl_str_mv |
2012-12-01 2014-05-27T11:27:23Z 2014-05-27T11:27:23Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://www.actaodontologicalat.com/archivo/v25n2/fulltext/art10.pdf Acta odontológica latinoamericana : AOL, v. 25, n. 2, p. 214-217, 2012. 0326-4815 http://hdl.handle.net/11449/73971 2-s2.0-84872683204 1411074363039082 |
url |
http://www.actaodontologicalat.com/archivo/v25n2/fulltext/art10.pdf http://hdl.handle.net/11449/73971 |
identifier_str_mv |
Acta odontológica latinoamericana : AOL, v. 25, n. 2, p. 214-217, 2012. 0326-4815 2-s2.0-84872683204 1411074363039082 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Acta Odontológica Latinoamericana (AOL) 0,264 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
214-217 |
dc.source.none.fl_str_mv |
Scopus reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
repositoriounesp@unesp.br |
_version_ |
1813546517381775360 |