Electrical Immunosensor Made with Antigenic Peptide NS5A-1 Immobilized onto Silk Fibroin for Diagnosing Hepatitis C
Autor(a) principal: | |
---|---|
Data de Publicação: | 2018 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNESP |
Texto Completo: | http://dx.doi.org/10.21577/0103-5053.20180080 http://hdl.handle.net/11449/164825 |
Resumo: | Immunosensors based on impedance spectroscopy for diagnosing hepatitis C are reported where the sensing units were made with the antigenic peptide PPLLESWKDPDYVPPWHG (NS5A-1) derived from the NS5A protein of the hepatitis C virus (HCV) immobilized in layer-by-layer (LbL) films with silk fibroin (SF) and deposited on gold interdigitated electrodes. The electrical response of the sensing units varied upon immersion into solutions containing the antibody anti-HCV owing to the biomolecular recognition of NS5A-1. This was associated with morphological changes on the LbL films caused by adsorption of NS5A-1 and inferred from atomic force microscopy images. Buffer solutions with different anti-HCV concentrations down to 2 ng mL(-1) could be clearly distinguished by analyzing the impedance spectroscopy data with a multidimensional projection technique. The specificity toward anti-HCV antibodies was confirmed in control experiments where no significant changes in the electrical response were measured by exposing the sensing units to solutions containing an anti-human immunodeficiency virus (HIV) antibody. The high sensitivity and selectivity of the units made with LbL films demonstrate the feasibility of measuring electrical impedance as an immunosensing strategy to detect hepatitis C. |
id |
UNSP_fcea04ccd421de8ce404215b3e3f1167 |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/164825 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
Electrical Immunosensor Made with Antigenic Peptide NS5A-1 Immobilized onto Silk Fibroin for Diagnosing Hepatitis Cimmunosensorlayer-by-layer filmantigenic peptidehepatitis Cimpedance spectroscopyImmunosensors based on impedance spectroscopy for diagnosing hepatitis C are reported where the sensing units were made with the antigenic peptide PPLLESWKDPDYVPPWHG (NS5A-1) derived from the NS5A protein of the hepatitis C virus (HCV) immobilized in layer-by-layer (LbL) films with silk fibroin (SF) and deposited on gold interdigitated electrodes. The electrical response of the sensing units varied upon immersion into solutions containing the antibody anti-HCV owing to the biomolecular recognition of NS5A-1. This was associated with morphological changes on the LbL films caused by adsorption of NS5A-1 and inferred from atomic force microscopy images. Buffer solutions with different anti-HCV concentrations down to 2 ng mL(-1) could be clearly distinguished by analyzing the impedance spectroscopy data with a multidimensional projection technique. The specificity toward anti-HCV antibodies was confirmed in control experiments where no significant changes in the electrical response were measured by exposing the sensing units to solutions containing an anti-human immunodeficiency virus (HIV) antibody. The high sensitivity and selectivity of the units made with LbL films demonstrate the feasibility of measuring electrical impedance as an immunosensing strategy to detect hepatitis C.Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)LMF/LNNano, BrazilUniv Estadual Paulista, Inst Quim, BR-14800060 Araraquara, SP, BrazilUniv Fed Mato Grosso do Sul, Inst Fis, CP-549, BR-79070900 Campo Grande, MS, BrazilUniv Sao Paulo, Inst Ciencias Matemat & Comp, BR-13566590 Sao Carlos, SP, BrazilUniv Sao Paulo, Inst Fis Sao Carlos, BR-13566590 Sao Carlos, SP, BrazilUniv Fed Sao Paulo, Inst Ciencia & Tecnol, BR-12231280 Sao Jose Dos Campos, SP, BrazilUniv Estadual Paulista, Inst Quim, BR-14800060 Araraquara, SP, BrazilCAPES: 26LMF/LNNano, Brazil: LMF 12298Soc Brasileira QuimicaUniversidade Estadual Paulista (Unesp)Universidade Federal de Mato Grosso do Sul (UFMS)Universidade de São Paulo (USP)Universidade Federal de São Paulo (UNIFESP)Lima, Lais R. [UNESP]Goncalves, Alem-Mar B.Paulovich, FernandoOliveira Jr, Osvaldo N.Ribeiro, Sidney J. L. [UNESP]Moraes, Marli L.2018-11-26T22:40:49Z2018-11-26T22:40:49Z2018-10-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article2054-2059application/pdfhttp://dx.doi.org/10.21577/0103-5053.20180080Journal Of The Brazilian Chemical Society. Sao Paulo: Soc Brasileira Quimica, v. 29, n. 10, p. 2054-2059, 2018.0103-5053http://hdl.handle.net/11449/16482510.21577/0103-5053.20180080S0103-50532018001002054WOS:000442564900007S0103-50532018001002054.pdfWeb of Sciencereponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengJournal Of The Brazilian Chemical Societyinfo:eu-repo/semantics/openAccess2023-10-29T06:07:25Zoai:repositorio.unesp.br:11449/164825Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T16:20:53.912875Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
Electrical Immunosensor Made with Antigenic Peptide NS5A-1 Immobilized onto Silk Fibroin for Diagnosing Hepatitis C |
title |
Electrical Immunosensor Made with Antigenic Peptide NS5A-1 Immobilized onto Silk Fibroin for Diagnosing Hepatitis C |
spellingShingle |
Electrical Immunosensor Made with Antigenic Peptide NS5A-1 Immobilized onto Silk Fibroin for Diagnosing Hepatitis C Lima, Lais R. [UNESP] immunosensor layer-by-layer film antigenic peptide hepatitis C impedance spectroscopy |
title_short |
Electrical Immunosensor Made with Antigenic Peptide NS5A-1 Immobilized onto Silk Fibroin for Diagnosing Hepatitis C |
title_full |
Electrical Immunosensor Made with Antigenic Peptide NS5A-1 Immobilized onto Silk Fibroin for Diagnosing Hepatitis C |
title_fullStr |
Electrical Immunosensor Made with Antigenic Peptide NS5A-1 Immobilized onto Silk Fibroin for Diagnosing Hepatitis C |
title_full_unstemmed |
Electrical Immunosensor Made with Antigenic Peptide NS5A-1 Immobilized onto Silk Fibroin for Diagnosing Hepatitis C |
title_sort |
Electrical Immunosensor Made with Antigenic Peptide NS5A-1 Immobilized onto Silk Fibroin for Diagnosing Hepatitis C |
author |
Lima, Lais R. [UNESP] |
author_facet |
Lima, Lais R. [UNESP] Goncalves, Alem-Mar B. Paulovich, Fernando Oliveira Jr, Osvaldo N. Ribeiro, Sidney J. L. [UNESP] Moraes, Marli L. |
author_role |
author |
author2 |
Goncalves, Alem-Mar B. Paulovich, Fernando Oliveira Jr, Osvaldo N. Ribeiro, Sidney J. L. [UNESP] Moraes, Marli L. |
author2_role |
author author author author author |
dc.contributor.none.fl_str_mv |
Universidade Estadual Paulista (Unesp) Universidade Federal de Mato Grosso do Sul (UFMS) Universidade de São Paulo (USP) Universidade Federal de São Paulo (UNIFESP) |
dc.contributor.author.fl_str_mv |
Lima, Lais R. [UNESP] Goncalves, Alem-Mar B. Paulovich, Fernando Oliveira Jr, Osvaldo N. Ribeiro, Sidney J. L. [UNESP] Moraes, Marli L. |
dc.subject.por.fl_str_mv |
immunosensor layer-by-layer film antigenic peptide hepatitis C impedance spectroscopy |
topic |
immunosensor layer-by-layer film antigenic peptide hepatitis C impedance spectroscopy |
description |
Immunosensors based on impedance spectroscopy for diagnosing hepatitis C are reported where the sensing units were made with the antigenic peptide PPLLESWKDPDYVPPWHG (NS5A-1) derived from the NS5A protein of the hepatitis C virus (HCV) immobilized in layer-by-layer (LbL) films with silk fibroin (SF) and deposited on gold interdigitated electrodes. The electrical response of the sensing units varied upon immersion into solutions containing the antibody anti-HCV owing to the biomolecular recognition of NS5A-1. This was associated with morphological changes on the LbL films caused by adsorption of NS5A-1 and inferred from atomic force microscopy images. Buffer solutions with different anti-HCV concentrations down to 2 ng mL(-1) could be clearly distinguished by analyzing the impedance spectroscopy data with a multidimensional projection technique. The specificity toward anti-HCV antibodies was confirmed in control experiments where no significant changes in the electrical response were measured by exposing the sensing units to solutions containing an anti-human immunodeficiency virus (HIV) antibody. The high sensitivity and selectivity of the units made with LbL films demonstrate the feasibility of measuring electrical impedance as an immunosensing strategy to detect hepatitis C. |
publishDate |
2018 |
dc.date.none.fl_str_mv |
2018-11-26T22:40:49Z 2018-11-26T22:40:49Z 2018-10-01 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.21577/0103-5053.20180080 Journal Of The Brazilian Chemical Society. Sao Paulo: Soc Brasileira Quimica, v. 29, n. 10, p. 2054-2059, 2018. 0103-5053 http://hdl.handle.net/11449/164825 10.21577/0103-5053.20180080 S0103-50532018001002054 WOS:000442564900007 S0103-50532018001002054.pdf |
url |
http://dx.doi.org/10.21577/0103-5053.20180080 http://hdl.handle.net/11449/164825 |
identifier_str_mv |
Journal Of The Brazilian Chemical Society. Sao Paulo: Soc Brasileira Quimica, v. 29, n. 10, p. 2054-2059, 2018. 0103-5053 10.21577/0103-5053.20180080 S0103-50532018001002054 WOS:000442564900007 S0103-50532018001002054.pdf |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Journal Of The Brazilian Chemical Society |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
2054-2059 application/pdf |
dc.publisher.none.fl_str_mv |
Soc Brasileira Quimica |
publisher.none.fl_str_mv |
Soc Brasileira Quimica |
dc.source.none.fl_str_mv |
Web of Science reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
|
_version_ |
1808128636461514752 |