Marginal fit of implant-supported fixed prosthesis frameworks with prefabricated and calcinable cylinders

Detalhes bibliográficos
Autor(a) principal: Alonso, Fernando Rizzo
Data de Publicação: 2008
Outros Autores: Triches, Diego Fernandes, Teixeira, Eduardo Rolim, Hirakata, Luciana Mayumi
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Revista odonto ciência (Online)
Texto Completo: https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/2680
Resumo: Purpose: The aim of this study was to evaluate the vertical marginal misfit of the metal framework of an implant-supported prosthesis. Methods: Ten frameworks were made of cobalt-chromium alloy (Co-Cr), simulating a three-element fixed prosthesis on two implants. Five frameworks were constructed using prefabricated cylinders, and the other five were constructed using calcinable cylinders. All frameworks were cast by the induction technique and laser-welded. Marginal misfit was measured by means of scanning electron microscopy with the frameworks subjected to the single-screw test. Twenty-five measurements of marginal fit were recorded per abutment and averaged for statistical analysis (ANOVA, α=0.05). Results: There was no statistically significant difference in marginal fit between the groups tested. The only difference found was when comparing the abutments with and without screw. Conclusion: It was concluded that there is no difference in marginal fit between frameworks cast in Co-Cr with calcinable and prefabricated cylinders using induction casting, laser-welding, and single-screw test. Key words: Dental implants; passive fit; manual rectification
id PUC_RS-22_ade87ccab36ea5d81b7aeb0015d1b2f4
oai_identifier_str oai:ojs.revistaseletronicas.pucrs.br:article/2680
network_acronym_str PUC_RS-22
network_name_str Revista odonto ciência (Online)
repository_id_str
spelling Marginal fit of implant-supported fixed prosthesis frameworks with prefabricated and calcinable cylindersAdaptação marginal de infra-estruturas de prótese fixa implanto-suportada com cilindros pré-usinados e calcináveisDental implantspassive fitmanual rectificationdental implantsPurpose: The aim of this study was to evaluate the vertical marginal misfit of the metal framework of an implant-supported prosthesis. Methods: Ten frameworks were made of cobalt-chromium alloy (Co-Cr), simulating a three-element fixed prosthesis on two implants. Five frameworks were constructed using prefabricated cylinders, and the other five were constructed using calcinable cylinders. All frameworks were cast by the induction technique and laser-welded. Marginal misfit was measured by means of scanning electron microscopy with the frameworks subjected to the single-screw test. Twenty-five measurements of marginal fit were recorded per abutment and averaged for statistical analysis (ANOVA, α=0.05). Results: There was no statistically significant difference in marginal fit between the groups tested. The only difference found was when comparing the abutments with and without screw. Conclusion: It was concluded that there is no difference in marginal fit between frameworks cast in Co-Cr with calcinable and prefabricated cylinders using induction casting, laser-welding, and single-screw test. Key words: Dental implants; passive fit; manual rectificationObjetivo: O objetivo deste trabalho foi avaliar o desajuste marginal vertical de infra-estruturas metálicas de prótese fixa sobre implantes. Metodologia: Foram confeccionadas 10 infra-estruturas em liga de cobalto-cromo (Co-Cr), simulando uma prótese fixa de três elementos sobre dois implantes, com o auxílio de uma matriz metálica. Cinco infra-estruturas foram confeccionadas com cilindros pré-usinados. Outras cinco foram confeccionadas com cilindros calcináveis. Todas as infra-estruturas foram fundidas pela técnica de indução e soldadas a laser. As leituras do desajuste marginal foram realizadas através de microscopia eletrônica de varredura, utilizando a técnica do parafuso único, totalizando 25 medições em cada cilindro. As médias de desajuste marginal de cada cilindro foram utilizadas para a análise estatística (ANOVA, α=0,05). Resultados: Não houve diferença estatística no grau de desajuste marginal entre os grupos testados. Apenas houve diferença quando comparados os cilindros com e sem parafuso. Conclusão: Foi concluído que não há diferença de adaptação marginal entre as infra-estruturas fundidas em Co-Cr com cilindros calcináveis e pré-usinados, utilizando fundição por indução, soldagem a laser e teste do parafuso único. Palavras-chave: Adaptação passiva; implantes dentários; desajuste marginalEDIPUCRS - Editora Universitária da PUCRS2008-07-14info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionPeer-reviewed Articlelaboratoryapplication/pdfhttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/2680Revista Odonto Ciência; Vol. 23 No. 4 (2008); 320 - 324Revista Odonto Ciência; v. 23 n. 4 (2008); 320 - 3241980-65230102-9460reponame:Revista odonto ciência (Online)instname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)instacron:PUC_RSenghttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/2680/3427Alonso, Fernando RizzoTriches, Diego FernandesTeixeira, Eduardo RolimHirakata, Luciana Mayumiinfo:eu-repo/semantics/openAccess2013-11-18T10:32:04Zoai:ojs.revistaseletronicas.pucrs.br:article/2680Revistahttps://revistaseletronicas.pucrs.br/ojs/index.php/foPRIhttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/oai||odontociencia@pucrs.br1980-65230102-9460opendoar:2013-11-18T10:32:04Revista odonto ciência (Online) - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)false
dc.title.none.fl_str_mv Marginal fit of implant-supported fixed prosthesis frameworks with prefabricated and calcinable cylinders
Adaptação marginal de infra-estruturas de prótese fixa implanto-suportada com cilindros pré-usinados e calcináveis
title Marginal fit of implant-supported fixed prosthesis frameworks with prefabricated and calcinable cylinders
spellingShingle Marginal fit of implant-supported fixed prosthesis frameworks with prefabricated and calcinable cylinders
Alonso, Fernando Rizzo
Dental implants
passive fit
manual rectification
dental implants
title_short Marginal fit of implant-supported fixed prosthesis frameworks with prefabricated and calcinable cylinders
title_full Marginal fit of implant-supported fixed prosthesis frameworks with prefabricated and calcinable cylinders
title_fullStr Marginal fit of implant-supported fixed prosthesis frameworks with prefabricated and calcinable cylinders
title_full_unstemmed Marginal fit of implant-supported fixed prosthesis frameworks with prefabricated and calcinable cylinders
title_sort Marginal fit of implant-supported fixed prosthesis frameworks with prefabricated and calcinable cylinders
author Alonso, Fernando Rizzo
author_facet Alonso, Fernando Rizzo
Triches, Diego Fernandes
Teixeira, Eduardo Rolim
Hirakata, Luciana Mayumi
author_role author
author2 Triches, Diego Fernandes
Teixeira, Eduardo Rolim
Hirakata, Luciana Mayumi
author2_role author
author
author
dc.contributor.author.fl_str_mv Alonso, Fernando Rizzo
Triches, Diego Fernandes
Teixeira, Eduardo Rolim
Hirakata, Luciana Mayumi
dc.subject.por.fl_str_mv Dental implants
passive fit
manual rectification
dental implants
topic Dental implants
passive fit
manual rectification
dental implants
description Purpose: The aim of this study was to evaluate the vertical marginal misfit of the metal framework of an implant-supported prosthesis. Methods: Ten frameworks were made of cobalt-chromium alloy (Co-Cr), simulating a three-element fixed prosthesis on two implants. Five frameworks were constructed using prefabricated cylinders, and the other five were constructed using calcinable cylinders. All frameworks were cast by the induction technique and laser-welded. Marginal misfit was measured by means of scanning electron microscopy with the frameworks subjected to the single-screw test. Twenty-five measurements of marginal fit were recorded per abutment and averaged for statistical analysis (ANOVA, α=0.05). Results: There was no statistically significant difference in marginal fit between the groups tested. The only difference found was when comparing the abutments with and without screw. Conclusion: It was concluded that there is no difference in marginal fit between frameworks cast in Co-Cr with calcinable and prefabricated cylinders using induction casting, laser-welding, and single-screw test. Key words: Dental implants; passive fit; manual rectification
publishDate 2008
dc.date.none.fl_str_mv 2008-07-14
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
Peer-reviewed Article
laboratory
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/2680
url https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/2680
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/2680/3427
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv EDIPUCRS - Editora Universitária da PUCRS
publisher.none.fl_str_mv EDIPUCRS - Editora Universitária da PUCRS
dc.source.none.fl_str_mv Revista Odonto Ciência; Vol. 23 No. 4 (2008); 320 - 324
Revista Odonto Ciência; v. 23 n. 4 (2008); 320 - 324
1980-6523
0102-9460
reponame:Revista odonto ciência (Online)
instname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
instacron:PUC_RS
instname_str Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
instacron_str PUC_RS
institution PUC_RS
reponame_str Revista odonto ciência (Online)
collection Revista odonto ciência (Online)
repository.name.fl_str_mv Revista odonto ciência (Online) - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
repository.mail.fl_str_mv ||odontociencia@pucrs.br
_version_ 1754820874244980736